Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability
Summary
| CVE | CVE-2026-3561 |
|---|---|
| State | PUBLISHED |
| Assigner | zdi |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-03-16 14:19:52 UTC |
| Updated | 2026-04-27 14:30:01 UTC |
| Description | Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479. |
Risk And Classification
Primary CVSS: v3.0 8 HIGH from [email protected]
CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS: 0.001510000 probability, percentile 0.353920000 (date 2026-04-27)
Problem Types: CWE-122 | CWE-122 CWE-122: Heap-based Buffer Overflow
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.0 | [email protected] | Secondary | 8 | HIGH | CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| 3.0 | CNA | CVSS | 8 | HIGH | CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
CVSS v3.0 Breakdown
Attack Vector
AdjacentAttack Complexity
LowPrivileges Required
LowUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Philips | Hue Bridge V2 | - | All | All | All |
| Operating System | Philips | Hue Bridge V2 Firmware | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Philips | Hue Bridge | affected 1.73.1973146020 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.zerodayinitiative.com/advisories/ZDI-26-159 | [email protected] | www.zerodayinitiative.com | Third Party Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.